105
Parameter list
Parameter list
5
ADJUSTMENT
Function assignment of external terminal and control — Function assignment of output
terminals (Pr.190 to Pr.196)
190
RUN terminal function
selection
10
0 to 5, 7, 8,
10 to 19, 25,
26, 45 to 48,
57, 64, 67,
70, 79, 85,
90 to 96, 98,
99,
100 to 105,
107, 108,
110 to 116,
125, 126,
145 to 148,
157, 164, 167,
170, 179, 185,
190 to 196,
198, 199,
9999
0, 100: Inverter running (RUN)
1, 101: Up to frequency (SU)
2, 102: Instantaneous power failure/
undervoltage (IPF)
3, 103: Overload warning (OL)
4, 104: Output frequency detection (FU)
5, 105: Second output frequency detection
(FU2)
7, 107: Regenerative brake pre-alarm (RBP)
(Only for the 75K or higher)
8, 108: Electronic thermal relay function
prealarm (THP)
10, 110: PU operation mode (PU)
11, 111: Inverter operation ready (RY)
12, 112: Output current detection (Y12)
13, 113: Zero current detection (Y13)
14, 114: PID lower limit (FDN)
15, 115: PID upper limit (FUP)
16, 116: PID forward/reverse rotation output
(RL)
17, —: Electronic bypass MC1 (MC1) *
18, —: Electronic bypass MC2 (MC2) *
19, —: Electronic bypass MC3 (MC3) *
25, 125: Fan fault output (FAN)
26, 126: Heatsink overheat pre-alarm (FIN)
45, 145: Inverter running and start command is
ON(RUN3)
46, 146: During deceleration at occurrence of
power failure (retained until release)
(Y46)
47, 147: During PID control activated (PID)
48, 148: PID deviation limit (Y48)
57, 157: IPM motor control (IPM)
64, 164: During retry (Y64)
67, 167: During power failure (Y67)
70, 170: PID output interruption (SLEEP)
79, 179: Pulse train output of output power
(Y79)
85, 185: DC current feeding (Y85)
90, 190: Life alarm (Y90)
91, 191: Fault output 3 (power-OFF signal)
(Y91)
92, 192: Energy saving average value updated
timing (Y92)
93, 193: Current average monitor signal (Y93)
94, 194: Fault output 2 (ALM2)
95, 195: Maintenance timer signal (Y95)
96, 196: Remote output (REM)
98, 198: Alarm output (LF)
99, 199: Fault output (ALM)
9999: No function
0 to 99: Positive logic, 100 to 199: Negative
logic
* Available under V/F control and Simple
magnetic flux vector control
×
191
SU terminal function
selection
11
×
192
IPF terminal function
selection
12
×
193
OL terminal function
selection
13
×
194
FU terminal function
selection
14
×
195
ABC1 terminal
function selection
199
0 to 5, 7, 8,
10 to 19,
25, 26,
45 to 48, 57,
64, 67, 70, 79,
85, 90, 91,
94 to 96,
98, 99,
100 to 105,
107, 108,
110 to 116,
125, 126,
145 to 148,
157, 164, 167,
170, 179, 185,
190, 191,
194 to 196,
198, 199, 9999
×
196
ABC2 terminal
function selection
1 9999
×
232 to 239
Refer to Pr.4 to Pr.6.
240
Refer to Pr.72.
241
Refer to Pr.125 and Pr.126.
242, 243
Refer to Pr.73.
Parameter
Name
Incre-
ments
Initial
Value
Range Description
Parameter
copy
Parameter
clear
All parameter
clear
Related
parameters
: enabled
× : disabled