Mitsubishi Electronics FR-F700P Microwave Oven User Manual


 
115
Parameter list
Parameter list
5
ADJUSTMENT
IPM motor control IPM parameter initialization (Pr.998)
998
IPM parameter
initialization
10
0
Parameter settings for a general-purpose
motor (frequency)

1
Parameter settings for a high-efficiency IPM
motor MM-EF (rotations per minute)
12
Parameter settings for a premium
high-efficiency IPM motor MM-EFS
(rotations per minute)
101
Parameter settings for a high-efficiency IPM
motor MM-EF (frequency)
112
Parameter settings for a premium
high-efficiency IPM motor MM-EFS (frequency)
Useful functions Automatic parameter setting (Pr.999)
999
Automatic parameter
setting
1 9999
10 GOT initial setting (PU connector)
×××
11 GOT initial setting (RS-485 terminals)
20 Rated frequency is 50Hz
21 Rated frequency is 60Hz
30
Acceleration/deceleration time
(0.1s increment)
31
Acceleration/deceleration time
(0.01s increment)
9999 No action
Useful functions Parameter clear, parameter copy, initial value change list, and auto-
matic parameter setting (Pr.CL, ALLC, Er.CL, PCPY, Pr.CH, IPM, AUTO)
Pr.CL
Parameter clear
100, 1
Setting "1" returns all parameters except calibration parameters to
the initial values.
ALLC
All parameter clear
1 0 0, 1 Setting "1" returns all parameters to the initial values.
Er.CL
Faults history clear
1 0 0, 1 Setting "1" will clear eight past faults.
PCPY
Parameter copy
10
0 Cancel
1 Read the source parameters to the operation panel.
2
Write the parameters copied to the operation panel to the
destination inverter.
3 Verify parameters in the inverter and operation panel.
Pr.CH
Initial value change
list
--- --- ---
Changed parameters (changed from the initial settings) are
displayed or set.
IPM
IPM parameter
initialization
1 0 0, 1, 12
When "1 or 12" is set, the parameters required to drive an IPM
motor are automatically changed as a batch.
AUTO
Automatic parameter
setting
--- --- ---
Parameter settings are changed as a batch. Those include
communication parameter settings for a GOT connection, rated
frequency settings of 50Hz/60Hz, and acceleration/deceleration
time increment settings.
Parameter
Name
Incre-
ments
Initial
Value
Range Description
Parameter
copy
Parameter
clear
All parameter
clear
Related
parameters
: enabled
× : disabled