Setting procedure of IPM motor control
<IPM>
(1) IPM motor control setting by selecting the parameter setting mode on the operation panel
()
(2) IPM motor control display and IPM motor control signal
P.RUN on the operation panel (FR-DU07) is lit and the IPM motor control signal (IPM) is output during IPM motor control.
For the terminal to output the IPM motor control signal, assign the function by setting "57 (positive logic)" or "157
(negative logic)" to any of Pr.190 to Pr.196 (Output terminal function selection).
POINT
· The parameters required to drive an IPM motor are automatically changed as a batch. (Refer to page 43.)
Operation example
Initialize the parameter setting for a premium high-efficiency IPM motor (MM-EFS) by selecting the parameter
setting mode on the operation panel.
Setting Description
0 Parameter settings for a general-purpose motor
1 Parameter settings for a high-efficiency IPM motor MM-EF (rotations per minute)
12 Parameter settings for a premium high-efficiency IPM motor MM-EFS (rotations per minute)
REMARKS
· Performing IPM parameter initialization by selecting the parameter setting mode on the operation panel automatically changes
the Pr. 998 IPM parameter initialization setting.
· The parameter initialization sets the same capacity as the inverter capacity to
Pr. 80 Motor capacity
. To use a 0.4kW MM-EF, set
Pr. 80
Motor capacity
= "0.4" before performing IPM parameter initialization by selecting the parameter setting mode on the operation panel.
· The IPM parameter setting is displayed as "1, 12" in the parameter setting mode even if
Pr.998 IPM parameter initialization
= "101, 112."
Display
Operation
Flicker ... Parameter setting complete!!
Turn to read another parameter.
Press twice to show the automatic parameter setting (AUTO).
Press to show the setting again.
The parameter
number read
previously appears.
P.RUN indicator is lit.
1. Screen at power-ON
The monitor display appears.
2. Parameter setting mode
Press to choose the parameter setting
mode.
3. Selecting the parameter
Turn until (IPM parameter
initialization) appears.
4. Displaying the setting
Press to read the currently set value.
" " (initial value) appears.
5. Selecting the setting
Turn to change it to the set value " ".
6. Parameter setting
Press to set.