Useful functions To display life of inverter parts (Pr.255 to Pr.259)
255
Life alarm status
display
1 0 (0 to 15)
Displays whether the control circuit capacitor, main
circuit capacitor, cooling fan, and each parts of the
inrush current limit circuit has reached the life alarm
output level or not.
×××
256
Inrush current limit
circuit life display
1% 100% (0 to 100%)
Displays the deterioration degree of the inrush
current limit circuit. Reading only
×××
257
Control circuit
capacitor life display
1% 100% (0 to 100%)
Displays the deterioration degree of the control
circuit capacitor. Reading only
×××
258
Main circuit capacitor
life display
1% 100% (0 to 100%)
Displays the deterioration degree of the main
circuit capacitor. Reading only
The value measured by Pr. 259 is displayed.
×××
259
Main circuit capacitor
life measuring
100, 1
Start measuring the main circuit capacitor life.
Switch the power supply ON again and check
the Pr. 259 setting. Measurement is complete if
the setting is "3". Set the deterioration degree
in Pr.258.

260
Refer to Pr.72.
Motor brake and stop operation Decelerate the motor to a stop at instantaneous
power failure (Pr.261 to Pr.266)
Operation selection at power failure and instantaneous power failure Decelerate the
motor to a stop at instantaneous power failure (Pr.261 to Pr.266)
261
Power failure stop
selection
10
Operation at
undervoltage
or power
failure
At power restoration
during power failure
deceleration
Deceleration
time to a stop

0
Coasts to a stop Coasts to a stop
-
1
Decelerates
to a stop
Decelerates to a stop
Depends on
Pr. 262 to Pr.
266 settings
2
Decelerates
to a stop
Accelerates again
Depends on
Pr. 262 to Pr.
266 settings
21
Decelerates
to a stop
Decelerates to a stop
Automatically
adjusts the
deceleration
time
22
Decelerates
to a stop
Accelerates again
Automatically
adjusts the
deceleration
time
262
Subtracted frequency
at deceleration start
0.01Hz 3Hz 0 to 20Hz
Normally operation can be performed with the
initial value unchanged. But adjust the frequency
according to the magnitude of the load
specifications (moment of inertia, torque).

263
Subtraction starting
frequency
0.01Hz 60Hz *
0 to 400Hz
When output frequency Pr.263
Decelerate from the speed obtained from
(output frequency - Pr.262).
When output frequency < Pr.263
Decelerate from output frequency

9999
Decelerate from the speed obtained from
(output frequency - Pr.262).
264
Power-failure
deceleration time 1
0.1/
0.01s
5s
0 to 3600/
360s
Set a deceleration slope down to the frequency
set in Pr.266.

265
Power-failure
deceleration time 2
0.1/
0.01s
9999
0 to 3600/
360s
Set a deceleration slope below the frequency
set in Pr.266.

9999 Same slope as in Pr.264
Parameter
Name
Incre-
ments
Initial
Value
Range Description
Parameter
copy
Parameter
clear
All parameter
clear
Related
parameters
: enabled