Taylor 047772-M Freezer User Manual


 
17
Model PH90 Important: To the Operator
Adjustable Draw Handle
The soft serve side of the freezer features an
adjustable d raw handle to provide the best portion
control, giving a better, consistent quality to your
product and controlling costs. The draw handle should
be adjusted to provide a flow rate of 5 to 7--1/2 oz. of
product by weight per 10 seconds. To INCREASE the
flow rate, turn the screw COUNTERCLOCKWISE,
and CLOCKWISE to DECREASE the flow rate. In
addition, for purposes of SANITIZING and RINSING,
the flow rate can be increased by removing the pivot
pin and placing the restrictive bar on the TOP. When
drawing product, always have the restrictive bar on
the BOTTOM.
IMPORTANT: Once the draw rate is
set, tighten the lock nut with a wrench.
Operating Screen Descriptions
When the machine is powered the system will initialize.
The screen will display “INITIALIZING”. There will be
four types of data the system will check: LANGUAGE,
SYSTEM DATA, CONFIG DATA, and LOCKOUT
DATA. During the INITIALIZING... LANGUAGE
screen, the alarm will be on. If the system data,
configuration data, or lockout history data has become
corrupt, the following screen will alert the operator that
the system settings may have been changed.
NVRAM FAULT
RESET TO DEFAULTS
PRESS SEL KEY
Once the system has initialized the SAFETY
TIMEOUT screen is displayed and the alarm is turned
on.
SAFETY TIMEOUT
ANY KEY ABORTS
This screen will be displayed, with the alarm on, for 60
seconds or until any keypad is pressed.
After the safety timeout has been completed, and the
power switch is OFF, one of the following screens is
displayed.
The first screen is displayed if the machine is not in a
brush clean state. If any of the requirements for a
brush clean have not been met, the time displayed will
remain at 5:00 minutes. When all the requirements for
a brush cleaning are met, and the five minutes expire,
the screen will change to the second screen, which is
the standard power switch OFF screen.
POWER SWITCH OFF
OUT TIME: 4:40 OUT
68.5 HOPPER 62.1
69.5 BARREL 67.7
POWER SWITCH OFF
-- = -- = -- = -- = -- = --
UNIT CLEANED
When the power switch is set in the ON position, the
system mode of operation screen is displayed. In this
example, the machine is ON, but no mode of operation
has been selected. The second line of the display
indicates whether there is a sufficient supply of mix in
the hopper or if there is a LOW or OUT mix condition.
The third line of the display shows the temperature of
the mix hopper. After pressing the AUTO keypad, the
last line of the display shows the month and date
(MM = month, DD = day) that the machine needs to be
disassembled and brush cleaned.
OFF :MODE: OFF
OK :MIX: OK
40.0F HOPPER 40.0F
BRUSH CLEAN ON: MM/DD