Step 4
When ready to resume normal operation, press the
AUTO keypad. (See Figure 81.)
Note: This procedure should b e done 3--4 hours
before the first shake is served, to build up ice crystals.
Figure 8 1
Soft Serve Side
Step 1
Prepare a small amount of anapproved 100 PPM sani-
tizing solution (examples: Kay--5
R or Stera--
Sheen
R). USE WARM WATER AND FOLLOW THE
MANUFACTURER’S SPECIFICATIONS. Sanitizethe
design cap in this solution.
Step 2
Return to the freezer with a small amount of sanitizing
solution. Dip the door spout brush into the sanitizing
solution and brush clean the door spout, and bottom of
the draw valve. (See Figure 82.)
Note: To assure sanitary conditions are maintained,
brush clean each item for a total of 60 seconds,
repeatedly dipping the b rush in sanitizing solution.
Figure 8 2
Install the design cap on the freezer door spout. (See
Figure 83.) Rinse a single service towel in sanitizing
solution, and wipe down the freezer door and area
around the bottom of the freezer door. Replace the
front drip tray and splash shield.