Taylor 047772-M Freezer User Manual


 
41
Model PH90 Operating Procedures
Step 3
Important: Install the agitator back onto the
agitator drive shaft housing. Replace the hopper
cover . (See Figure 66.)
Figure 6 6
Step 4
Remove the syrup lines from the freezer door.
Step 5
Return to the freezer with a small amount of cleaning
solution. With a pail below the door spout, dip the door
spout brush into the cleaning solution and brush clean
the syrup ports in the freezer door, door spout and
bottom of the driven spinner, spinner blade, and syrup
line fittings. (See Figure 67.)
Note: To assure sanitary conditions are maintained,
brush each item for a total of 60 seconds, repeatedly
dipping the brush in cleaning solution.
Figure 6 7
With the syrup port brush, b rush each syrup port hole
10 to 15 times. Dip the b rush in the cleaning solution
before b rushing each port. (See Figure 68.)
Figure 6 8
Fill the squeeze bottle with cleaning solution. With a
pail beneath the door, insert the adapter end of the
squeeze bottle into the syrup port, and squeeze the
bottle firmly. This action will force solution out of the
adjacent port and down around the spinner. This
procedure should be performed for at least 10seconds
per port. (See Figure 69.)
Figure 6 9