21
Model PH90 Important: To the Operator
Screen “C” is SET CLOCK. This screen will display the
current date and time. The date and time may only be
changed after the freezer has been manually brush
cleaned but before it has been placed in the AUTO
mode. Move the cursor under the number you wish to
change. Press the plus keypad to increase the
number; press the minus keypad to decrease the
number . When the desired time and date appears,
press the SEL keypad once to return to the
OPERATOR MENU.
SET CLOCK
10:21 AM 11/07/1999
-- --
<------ ------> +++ ------ SEL
If an illegal date is entered, the following screen will
appear. The correct date must be entered before
leaving this display.
SET CLOCK
10:34 AM 02/30/1999
-- -- I N VA L I D D AT E
<------ ------> +++ ------ SEL
Screen “D” is SYSTEM INFO RMATION. The first
screen will indicate the software version used in the
unit.
SOFTWARE VERSION
PH90 Control UVC2
Version 2.00
SEL
Press the SEL keypad to view the second screen of the
SYSTEM INFORMATION display. This screen will
indicate the Bill of Material number and serial number
for the unit. Press the SEL keypad once to return to the
Operator Menu.
B.O.M. PH9033B000
S/N J0000000
SEL
Screen “E” is AUTO H EAT TIME. This screen is used
to set the time of day in which the heat treatment cycle
will start. Move the cursor under the number you wish
to change. Press the plus keypad to increase the
number; press the minus keypad to decrease the
number . When the desired time appears, press the
SEL keypad once to return to the OPERAT OR MENU.
AUTO HEAT TIME
TIME: 12:00 AM
-- --
<------ ------> +++ ------ SEL
Screen “F” is CURRENT CONDITIONS. This screen
gives the viscosity of the product and the hopper and
barrel temperatures. The last line of the display is the
compressor countdown safety timer. The safety timer
prevents the compressor from running more than 11
minutes (other than during the cooling phase of the
heat treatment cycle).
Press the SEL keypad once to view the SERVINGS
COUNTER screen.
VISC HOPPER BARREL
0 38.5 28.5
0.0 38.5 18.0
TIME C 11:00 11:00
The SERVINGS COUNTER screen indicates the
number of times the draw switch has closed (number
of draws) since the last brush cleaning or since the last
serving counter reset. A maximum of 32,767 draws
can be recorded; an additional draw will cause the
counter to restart at zero. Pressing the MENU
keypad/SEL will return the display t o the Operator
Menu.
SERVINGS COUNTER
LEFT RIGHT
12 15
SEL
Draws are counted during the AUTO m ode of
operation only.