Taylor 047772-M Freezer User Manual


 
18
Model PH90Important: To the Operator
010917
This display indicates the freezer is operating in 3
different modes. The following i nformation is given:
The left side of the freezer is operating in the
STANDBY mode, and the mix level in the hopper is
OUT. The right side is operating in the WASH and
PUMP modes, and the mix level in the hopper is LOW.
The temperature of the mix in both hoppers is 40_F.
(4.4_C.), and the machine needs to be brush cleaned
on October 31st.
STANDBY :MODE: WSH --PMP
OUT :MIX: LOW
40.0F HOPPER 40.0F
BRUSH CLEAN ON: 10/31
The following displays pertain to the HEAT cycle:
While in the heating phase, you will see this d isplay. It
shows the present temperature of the hopper.
HEAT :MODE: HEAT
HEAT :PHASE: HEAT
140.0F HOPPER 140.0F
BRUSH CLEAN ON: MM/DD
DO NOT draw product or attempt to
disassemble the unit during the HEAT cycle. The
product is hot and under extreme pressure.
The mix temperature must be raised above 151_F.
(66.1_C.) within 90 minutes or the freezer will be
locked in STANDBY, and the cycle failure display will
appear.
In the example, the hopper temperature is 140_F.
(60_C.). The phase shows that the machine is in the
HEAT phase of the treatment cycle.
When the heating phase is complete, the freezer goes
into the holding phase of the cycle. The holding phase
will hold the temperature above 151_F. (66.1_C.) for a
minimum of 30 minutes.
In this example, the hopper temperature is 151_F.
(66.1_C.).
HEAT :MODE: HEAT
HOLD :PHASE: HOLD
151.0F HOPPER 151.0F
BRUSH CLEAN ON: MM/DD
The final phase of the heat treatment cycle is the
cooling phase. Now the freezer must cool the mix
below 41_F. (5_C.). If the product fails to cool in 2
hours, the freezer will lock out.
This example illustrates that the temperature is being
lowered, but has not yet reached the set point.
HEAT :MODE: HEAT
COOL :PHASE: COOL
55.0F HOPPER 55.0F
BRUSH CLEAN ON: MM/DD
When the entire heat cycle has been completed, the
normal display will appear, showing the machine in the
STANDBY mode. The machine may now be placed in
AUTO or left in STANDBY.
STANDBY :MODE: STANDBY
OK :MIX: OK
41.0F HOPPER 41.0F
BRUSH CLEAN ON: MM/DD
Hard Lock: There a re two causes for a hard l ock:
1. Fourteen days have e lapsed since the last
brush cleaning. The following screen will be
displayed.
14 DAY TIMEOUT
CLEANING REQ’D
FREEZER LOCKED
PRESS SEL KEY
2. There has been a thermistor failure (freezing
cylinder, hopper, or glycol) during the heat
treatment process.
SYSTEM FAULT
SERVICE REQ’D
FREEZER LOCKED
PRESS SEL KEY
All four LED’s on the front of the freezer will light. Press
the SEL keypad.