Taylor 047772-M Freezer User Manual


 
42
Model PH90Operating Procedures
010917
Place the spout cap o--ring in the spout cap. Fill the
spout cap with sanitizing solution. While holding the
draw valve closed, install the spout cap over the end
of the door spout. This will cause sanitizing solution to
back flow through the syrup ports. (See Figure 70.)
Figure 7 0
Install the syrup hole plugs in the syrup ports in the
freezer door. (See Figure 71.)
Figure 7 1
Rinse a single service towel in cleaning solution and
wipe down the freezer door and area around the
bottom of the freezer door.
Soft Serve Side
THIS PROCEDURE MUST BE DONE ONCE EVERY
24 HOURS.
DO NOT draw product or attempt to
disassemble the unit during the HEAT cycle. The
product is hot and under extreme pressure.
Important: The level of mix in the mix hopper must be
above the mix low probe.
Note: If the CLEAN MANUALLY light is flashing, do
not add mix. The machine must be disassembled and
brush cleaned within 24 hours.
Both sides of the freezer must be in the AUTO mode
before the HEAT cycle may be started.
Step 1
Place the heater switches in the OFF position. (See
Figure 72.)
Figure 7 2
Step 2
Remove the hopper cover .
MAKE SURE YOUR HANDS ARE CLEAN AND
SANITIZED BEFORE PERFORMING THESE NEXT
STEPS.
Note: Pressing the CAL key will stop agitator
movement for 10 s econds. A t end of 10 seconds,
press the CAL key again to return to the mode screen.
Remove the agitator from the mix hopper. Remove the
design cap from the freezer door s pout. Take the
agitator, hopper cover and design cap to the sink for
further cleaning and sanitizing.