3M 39800 Food Saver User Manual


 
Safety Information 3M-Matic 800rf Case Sealer
viii Copyright 1999, 3M IPC. All rights reserved.
Tape Threading Label
The Tape Threading Label, shown in Figure 3, is
attached to the left side of both the upper and lower
taping heads. This label provides a convenient tape
threading diagram. More detailed tape loading and
threading information is provided in this manual in
Section 2, Installation.
STOP Switches
The Model 800rf Type 39800 Case Sealer is
equipped with three STOP switches. Their locations
are shown in Figure 4. Pressing either of the red E-
Stop switches stops the machine, removing electri-
cal power and air pressure from the case sealer. To
restart the machine, you must turn and release the E-
Stop switch and then press the RESET button and
the START button on the Electrical Control Panel.
Pressing the STOP button on the Electrical Control
Panel stops the machine and does not remove power
from the controller. To restart the machine, you must
press the RESET button and then the START button.
Figure 3. Tape Threading Label
Figure 4. STOP Switch Locations