3M-Matic 800rf Case Sealer Installation
Copyright 1999, 3M IPC. All rights reserved. 2-3
2-3. Setup Procedure
2-3-1. Case Sealer Bed Height
The legs on the case sealer can be adjusted to obtain
different bed heights from the factory set-point. The
bed height can be set from 25-7/8 inches [657 mm]
minimum through 32 inches [815 mm] maximum. Set
the bed height as follows:
1. Block up the case sealer frame to allow adequate
leg adjustment.
2. Using a 6 mm hex key wrench, loosen, but do not
remove, two M8 x 16 mm socket-head cap screws
in one leg. Refer to Figure 2-2.
Figure 2-2. Bed Height Adjustment
3. Using the height label as a guide, adjust the leg
length to the desired conveyor bed height. Re-
tighten the two screws to secure the leg.
4. Adjust the five remaining legs in the same way.
2-3-2. Rear Emergency Stop Switch
Installation
A latching Emergency Stop (E-Stop) switch is
electrically connected to the case sealer, but not
mounted to the machine. Install this E-Stop switch on
the rear side of the case sealer.
1. Remove the protective wrap from the E-Stop
switch and bracket assembly.
2. Secure the E-Stop switch bracket to the rear
sliding door support bracket with the socket-head
screw provided. Refer to Figure 2-3.
Figure 2-3. Rear E-Stop Switch Installation