3M 39800 Food Saver User Manual


 
3M-Matic 800rf Case Sealer Installation
Copyright 1999, 3M IPC. All rights reserved. 2-25
Installing Air On/Off Valve/Regulator/Filter
13. Locate the Air On/Off Valve/Regulator/Filter and
bracket.
14. Rotate the bracket 180°.
a. Remove the lower socket-head screw (4
mm) and loosen the upper screw, but do not
remove it. Refer to Figure 2-26.
b. Punch a hole in the label. Then rotate the
bracket 180°. The label will be upside-down
(a replacement label is available and may
be ordered as replacement parts are or-
dered).
c. Secure the Air On/Off Valve/Regulator/
Filter to the bracket by installing the lower
socket-head screw and tightening the upper
screw. Refer to Figure 2-27.
15. Mount the bracket with the Air On/Off Valve/
Regulator/Filter to the left bracket that supports
the Pneumatic Control Panel.
Figure 2-27. Air On/Off Valve/Regulator/Filter
and Bracket Rotated 180°
Figure 2-26. Air On/Off Valve/Regulator/Filter
and Bracket