2-26 Copyright 1999, 3M IPC. All rights reserved.
16. Remove and separate the Air On/Off Valve
from the Regulator/Filter.
a. Loosen the hex screw in the bracket that
holds the two assemblies together. Refer to
Figure 2-28.
b. Separate the Air On/Off Valve from the
Regulator/Filter by removing both assem-
blies from the bracket.
17. Rotate the Regulator/Filter assembly 180°.
a. Swap the air gauge and air plug. Do this by
unscrewing the gauge and the plug, then
install the gauge in the hole previously
containing the plug, and vice versa.
b. Remove the air outlet and install it on the
opposite side of the regulator body.
c. Remove the filter bowl and shield by sliding
the lock down, rotating the unit in either
direction, and separating the unit from the
regulator body.
d. Install the filter bowl and shield so the lock
is located directly under the gauge.
18. Install the Air On/Off Valve and Regulator/
Filter so the air outlet on the Regulator/Filter is
facing the Pneumatic Control Panel and the Air
On/Off Valve is facing the Electrical Control
Panel. Refer to Figure 2-29.
a. Place the two assemblies in the bracket that
holds them together and tighten the hex
screw.
Figurer 2-29. Air On/Off Valve/Regulator/Filter
Reconfigured
Figurer 2-28. Separate Air On/Off Valve from
Regulator/Filter
Installation 3M-Matic 800rf Case Sealer