3M 39800 Food Saver User Manual


 
Disassembly/Reassembly 3M-Matic 800rf Case Sealer
4-8 3M 1998 December
4-9.
Flap Folder Cylinder
Turn off the main air supply and electrical
power before removing any components.
Steps 1 through 3 on the figure below refer to
removal of the Flap Folder Cylinder.
1. Remove associated hardware, air lines, and flow
control valves.
2. If a flow control is replaced, adjust the new
flow control to match the one removed. Refer
to Flap Folder Arm and Flap Folder Flow
Controls  Speed Controls in Section 3.
4-10. Flap Folder Arm Cylinder
Turn off the main air supply and electrical
power before removing any components.
Steps 6 through 8 on the figure below refer to
removal of the Flap Folder Arm Cylinder.
1. Remove associated hardware, air lines, and flow
controls. Note the position of the limit switch
(sensor) attached to the cylinder housing so you
can install the switch at the same position on the
replacement cylinder. The position of the limit
switch affects cylinder extension, timing, etc.
2. If a flow control is replaced, adjust the new
flow control to match the one removed. Refer
to Flap Folder Arm and Flap Folder Flow
Controls  Speed Controls in Section 3.
Warning!
Warning!