Carrier 69NT40-521 Refrigerator User Manual


 
SECTION 3
3-33 T-268-07
Table 3-10. DataCORDER Pre- Trip Data
TEST # TITLE DATA
NOTE
“Auto” or “Auto1” menu includes the following: P, P1, P2, P 3, P4, P5, P6 and rSLts. “Auto2’ (Optional)
menu includes the following: P, P1, P2, P3, P4, P5, P6, P7, P8, P9, P10 and rSLts. (Refer to section 3.2.1.)
1-0 Heater On Pass/Fail/Skip Result, Change in current for Phase A, B and C
1-1 Heater Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C
2-0 Condenser Fan On Pass/Fail/Skip Result, Water pressure switch (WPS) -- Open/Closed,
Change in currents for Phase A, B and C
2-1 Condenser Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-0 Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-1 Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-0 High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-1 High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
5-0 Supply/Return Probe Test Pass/Fail/Skip Result, STS, RTS, SRS and RRS
5-1 Secondary Supply Probe Test Pass/Fail/Skip Result
5-2 Secondary Return Probe Test Pass/Fail/Skip Result
6-0 Compressor On -- High Speed Pass/Fail/Skip Result, Change in currents for Phase A, B and C
6-1 Compressor On -- Low Speed Pass/Fail/Skip Result, Change in currents for Phase A, B and C
6-2 Suction Modulation Valve
Open
Pass/Fail/Skip Result, STS, RTS, Is current limit in effect? (Y,N)?
6-4 Suction Modulation Valve
Closed
Pass/Fail/Skip Result, STS, RTS, Delta T1, Delta T2,
Is current limit in effect? (Y,N)?
6-5 Suction Solenoid Valve Open Pass/Fail/Skip Result, STS, RTS, Is current limit in effect? (Y,N)?
7-0 High Pressure Switch Closed
Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens?
7-1 High Pressure Switch Open
Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes?
8-0 Perishable Heat Pass/Fail/Skip Result, STS, time it takes to heat to 16_C(60_F)?
8-1 Perishable Pull Down Pass/Fail/Skip Result, STS, time it takes to pull down to 0_C(32_F)?
8-2 Perishable Maintain
Pass/Fail/Skip Result, Averaged DataCORDER supply temperature
(SRS) over last recording interval.
9-0 Defrost Test
Pass/Fail/Skip Result, DTS temperature at end of test, line voltage,
line frequency, time in defrost.
10-0 Frozen Mode Set-up Pass/Fail/Skip Result, STS, time unit is in heat.
10-1 Frozen Mode Pull Down Pass/Fail/Skip Result, STS, time to pull down unit to --17.8_C(0_F).
10-2 Frozen Mode Maintain
Pass/Fail/Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.