Carrier 69NT40-521 Refrigerator User Manual


 
SECTION 3
3-35 T-268-07
AIR
CIRCULATION
ONLY
SET POINT
FALLING
TEMPERATURE
RISING
TEMPERATURE
-- 1 . 5 _C(2.7_F)
-- 1 _C(1.8_ F)
-- 0 . 5 _C(0.9_F)
--0.20_C
+.20_C
+1.5_C(2.7_F)
+1_C(1.8_F)
+0.5_C(0.9_F)
COOLING
AIR
CIRCULATION
ONLY
COOLING
NOTE
For In-range Tolerance, Refer to section 3.1.4 Code 30.
Figure 3-4. Controller Set Point BELOW -- 10_C(+14_F), or --5_C(+23_F) optionally
SET POINT
FALLING
TEMPERATURE
RISING
TEMPERATURE
-- 1 . 5 _C(2.7_F)
-- 1 _C(1.8_ F)
-- 0 . 5 _C(0.9_F)
--0.20_C
+.20_C
+1.5_C(2.7_F)
+1_C(1.8_F)
+0.5_C(0.9_F)
HEATINGHEATING
MODULATING
COOLING *
AIR CIRCULATION ONLY
AIR CIRCULATION ONLY
MODULATING
COOLING *
NOTE
For In-range Tolerance, Refer to section 3.1.4 Code 30.
* For Two-Speed compressor operation refer to Figure 3-6.
Figure 3-5. Controller Set Point ABOVE --10_C(+14_F), or --5_C(+23_F) optiona lly