Agilent E1441A Error Messages 149
Appendix B
command only). An odd number of bytes is not accepted because the
function generator would not know how to interpret the last single byte.
810 State has not been stored
The memory location specified in the *RCL command was not used in a
previous *SAV command. You cannot recall the instrument state from a
memory location that was not previous specified as a storage location.
850 Cal setup invalid
851 Negative offset gain cal required (CAL:SETup 50)
852 Flatness DAC gain cal required (CAL:SETup 64)
853 AM cal 1 required (CAL:SETup 30)
854 AM cal 2 required (CAL:SETup 31)
855 Cal load resistance not specified (CAL:SETup 33)
856 Square wave positive offset cal required (CAL:SETup 60)
857 Square wave 50% duty cycle cal required (CAL:SETup 62)
Arbitrary Waveform Errors
The following errors indicate failures that may occur during an arbitrary
waveform download. Refer to the Arbitrary Waveform Commands for more
information specific to the use of arbitrary waveform commands. These
commands are summarized on page <Reference> in the "Table of Contents
by Function" for Chapter 3, SCPI Command Reference.
780 VOLATILE arb waveform has not been loaded
The DATA:COPY command copies the waveform downloaded into
VOLATILE memory to the specified name. You must download the
waveform using the DATA VOLATILE or DATA:DAC VOLATILE
command prior to a copy operation.
781 Not enough memory to store new arb waveform; use DATA:DELete
Up to four user-defined waveforms can be stored in non-volatile memory.
Use the DATA:DEL command to delete the waveform in
VOLATILE
memory or any of the four user-defined waveforms in non-volatile memory.
Use the DATA:CAT? command to list all waveforms currently stored in
volatile and non-volatile memory.
782 Cannot overwrite a built-in arb waveform
You cannot overwrite the names of the five built-in arbitrary waveforms.
The following names are reserved and cannot be used with the
DATA:COPY command:
SINC, NEG_RAMP, EXP_RISE, EXP_FALL, and
CARDIAC.