On-Line Help System Overview Introduction • 1-7
• MultiFlex I/O Board Installation and Operation
Manual (P/N 026-1704) - Installation and opera-
tion manual for the MultiFlex 16 and all versions of
the MultiFlex combination input/output board,
excluding unit controllers such as the CUB and
RTU.
• MultiFlex CUB/CUB II Condensing Unit Board
Installation and Operation Manual (P/N 026-
1705) - Installation and operation manual for the
MultiFlex CUB (old style) and the MultiFlex CUB-
II family, which includes the CUB-II and CUB-TD.
• MultiFlex RTU Rooftop Controller Installation
and Operation Manual (P/N 026-1706) - Installa-
tion and operation guide for the MultiFlex RTU
(replacement for ARTC).
• MultiFlex RCB Rooftop Controller Installation
and Operation Manual (P/N 026-1707) - An
improved version of the MultiFlex RTU, the RCB
has 16 fully configurable analog and digital input
points. The RCB also has four analog outputs for
use in controlling variable speed fans, economizers,
or modulating heating and/or cooling valves. The
RCB also features a more sophisticated HHT inter-
face and updated algorithms for controlling heating,
cooling, dehumidification, and air quality. Refer to
this manual for more information on the MultiFlex
RCB Rooftop Controller.
• E2 User’s Manual Supplement for Flexible Com-
biner Programming (P/N 026-1620) - The Flexible
Combiner application is an advanced I/O control
program used to combine multiple analog and digi-
tal input values using programmed equations simi-
lar to those used in spreadsheets, and is a new
feature of E2 versions 2.20 and above. Refer to this
manual for more information on the Flexible Com-
biner application.
• Facility Status Display (FSD) Installation and
Operation Manual (P/N 026-1400) - The FSD
reports alarm information and more, (such as tem-
peratures, occupancy, case status, and setpoints)
and provides a centralized device for store person-
nel to review information by communicating with
the E2 via Ethernet connectivity (minimum E2
firmware rev. 2.68F01). Refer to this manual for
more information on the Status Display application.
• Square D Smart Breaker Control Manual (P/N
026-1711) - The Smart Breaker products are
designed to allow the Retail Solutions family of site
controllers to command control panels (minimum
E2 firmware rev. 2.71F01). A breaker panel gener-
ally consists of a series of circuit breakers that are
flipped from OFF to ON and from ON to OFF by
commands sent from E2 through MODBUS or a
Square D Smart Breaker Gateway board. Refer to
this manual for more information on the Square D
Breaker Panel application.
• Eaton Breaker Control Manual (P/N 026-1709) -
E2 can communicate directly with Eaton's Breaker
Control Bus (BCB) modules. Communication with
the E2 (minimum E2 firmware rev. 2.82) will
enable users to access features such as Time Sched-
ules, Enhanced Lighting, and Logging, with the the
added capabilities of dial-out on failure and offsite
remote connection, specifically with UltraSite32
and Site Manager to the breaker panel. The Eaton
Breaker Panel controller is a licensed application
available in the E2 300 and 400 model controllers.
Refer to this manual for more information on the
Square D Breaker Panel application.
• Energy Meter Manual (P/N 026-1726) - The
Energy Meter provides a solution for measuring
energy data with a single device. Inputs include
Control Power, CT, and 3-phase voltage. The
Energy Meter supports multiple output options,
including solid state relay contacts, Modbus (with
or without data logging), and pulse. The LCD
screen on the faceplate allows instant output view-
ing.
• iPro DAC (P/N 026-1727) - The iPro DAC is a
packaged HVAC control board for use either as a
stand-alone controller or in zone control applica-
tions using a Retail Solutions E2 BX building con-
trol system. The iPro DAC is capable of controlling
heat and cool stages, fans, humidification and dehu-
midification devices and economizers using on-
board I/O and control algorithms, as well as moni-
tor and interact with other building control systems
and peripherals (such as smoke alarms and CO2
sensors).
1.6 On-Line Help System
Overview
The E2 On-Line Help is the primary source front-
panel/interface users will have to consult when seeking
instruction on properties, screens, menus, and trouble-
shooting of hardware/software problems. The on-line help
topics are designed to minimize the time the user would
otherwise have to spend searching through the manual to
find information. Press
+ keys to open the
General Help menu.