Wallboard Installation and Maintenance INDeX Wallboard 22
INDeX Contact Centre Modules Page 100
Installation & Maintenance 38HBK00001SCM - Issue 11 (05/01)
Network Address
OFF Position Represents 0
ON Position Represents 1
SW4 SW3 SW2 SW1 ADDRESS
0000 0
0001 1
0010 2
0011 3
0100 4
0101 5
0110 6
0111 7
1000 8
1001 9
1010 10
1011 11
1100 12
1101 13
1110 14
1111 15
Baud Rate
Dip Switch Settings are:
SW5 SW6 DATA BIT/SEC
OFF OFF 19200
ON OFF 9600
OFF ON 2400
ON ON 1200
Ensure the Baud rate is set to 9600.
Test Functions
SW7 SW8 FUNCTION
OFF OFF Normal Running
ON OFF Diagonal Stripe Test
OFF ON Full Screen LED Test
ON ON Information Screen
(Only on power up)
The information screen shows three pages where the following text is displayed.
The dip switches must be set with the display powered down, then switch power on
to achieve information screen.
Yellow Text Software Version
Sign Type
Green Text Network
Number
Red Text Baud
Rate