Mitsubishi Electronics SW2D5C-GTWK2-E Frozen Dessert Maker User Manual


 
5 - 34
5.2 Communication Setup
5.2.3 How to Set Up the Ethernet Connection
(3) IP address setting (Setting with remote monitor tool)
: Required : Set if necessary : Not required
(4) Setting on personal computer
Set the IP address.
(5) Communication check
(a) Ping test
The INIT.LED of the CNC C70 turns on when the CNC C70 is ready for communications.
When the CNC C70 is ready for communications, execute the Ping command with the
command prompt of Windows
.
When the Ping test is verified
C:\>Ping 192. 168. 0. 19
Reply from 192.168.0.19:bytes=32 time<10ms TTL=32
When the Ping test is not verified
C:\>Ping 192. 168. 0. 19
Request timed out.
Item Setting
Setting
(with GOT connected)
IP address 192.168.0.19
Subnet mask 255.255.255.0
Gateway address 0.0.0.0
Port number 64758 (Fixed)
Speed auto/10M 0 (Fixed)