Mitsubishi Electronics SW2D5C-GTWK2-E Frozen Dessert Maker User Manual


 
5 - 40
5.2 Communication Setup
5.2.3 How to Set Up the Ethernet Connection
(5) Setting on the personal computer
Set the IP address.
(6) Communications check
(a) Ping test
When ready to communicate, execute the Ping command at the command prompt on the
Windows .
When connections are OK
C:\>ping 192. 168. 0. 2
Reply from 192. 168. 0. 2:bytes=32 time<10ms TTL=32
When connections are not good
C:\>ping 192. 168. 0. 2
Request timed out.
When the Ping test is not verified, check the connections of the cable and module, and settings,
including the IP address, for Windows .
(b) Station monitoring function
For details on the station monitoring function, refer to the following manual.
GOT1000 Series Connection Manual
(7) Settings with GT Designer2 and GT SoftGOT1000
(a) Ethernet setting
Make the following settings on the Ethernet setting dialog box of GT Designer2.
Refer to the following for details of the Ethernet settings.
5.2.4 Setting on GT Designer2