Freescale Semiconductor DSP56364 Bread Maker User Manual


 
Power
DSP56364 24-Bit Digital Signal Processor Users Manual, Rev. 2
Freescale Semiconductor 2-3
2.2 Power
2.3 Ground
Table 2-2 Power Inputs
Power Name Description
V
CCP
PLL Power—V
CCP
is V
CC
dedicated for PLL use. The voltage should be well-regulated and the input
should be provided with an extremely low impedance path to the V
CC
power rail. There is one V
CCP
input.
V
CCQL
(4) Quiet Core (Low) Power—V
CCQL
is an isolated power for the internal processing logic. This input must
be tied externally to all other chip power inputs. The user must provide adequate external decoupling
capacitors. There are four V
CCQL
inputs.
V
CCQH
(4) Quiet External (High) Power—V
CCQH
is a quiet power source for I/O lines. This input must be tied
externally to all other chip power inputs. The user must provide adequate decoupling capacitors. There
are four V
CCQH
inputs.
V
CCA
(4) Address Bus Power—V
CCA
is an isolated power for sections of the address bus
I/O drivers. This input must be tied externally to all other chip power inputs. The user must provide
adequate external decoupling capacitors. There are four V
CCA
inputs.
V
CCD
(1) Data Bus Power—V
CCD
is an isolated power for sections of the data bus I/O drivers. This input must be
tied externally to all other chip power inputs. The user must provide adequate external decoupling
capacitors. There is one V
CCD
inputs.
V
CCC
(1) Bus Control Power—V
CCC
is an isolated power for the bus control I/O drivers. This input must be tied
externally to all other chip power inputs. The user must provide adequate external decoupling capacitors.
There is one V
CCC
inputs.
V
CCS
(3) SHI and ESAI —V
CCS
is an isolated power for the SHI and ESAI. This input must be tied externally to all
other chip power inputs
L
. The user must provide adequate external decoupling capacitors. There are
three V
CCS
inputs.
Table 2-3 Grounds
Ground Name Description
GND
P
PLL Ground—GND
P
is ground-dedicated for PLL use. The connection should be provided with an
extremely low-impedance path to ground. V
CCP
should be bypassed to GND
P
by a 0.47 µF capacitor
located as close as possible to the chip package. There is one GND
P
connection.
GND
Q
(4) Quiet Ground—GND
Q
is an isolated ground for the internal processing logic. This connection must be
tied externally to all other chip ground connections. The user must provide adequate external decoupling
capacitors. There are four GND
Q
connections.
GND
A (4)
Address Bus Ground—GND
A
is an isolated ground for sections of the address bus I/O drivers. This
connection must be tied externally to all other chip ground connections. The user must provide adequate
external decoupling capacitors. There are four GND
A
connections.
GND
D
(1) Data Bus Ground—GND
D
is an isolated ground for sections of the data bus
I/O drivers. This connection must be tied externally to all other chip ground connections. The user must
provide adequate external decoupling capacitors. There is one GND
D
connections.