Communication
Error No. Error message Error definition and cause Corrective action
0008
to
0014
Please make sure of
communicatoin.
Transfer data with the GOT has an
error.
Check the cable.
The cable is unplugged.
The cable is broken..
Check the cable.
The GOT is not responding.
Check the GOT condition.
0259
Timeout error
Communication with the GOT is
unstable. An error has occurred in
communication.
Set the lower "transmission speed"
in the "communication
configuration" than the current
value.
(
Section 5.2.1 Setting
communication)
0260
Port open error
Non-existing communication port is
set.
Set the port that connects the
communication cable to the GOT
to the "communication port" of the
"communication configuration".
(
Section 5.2.1 Setting
communication)
0263
Recieve error
Data cannot be received from the
GOT.
Data received from the GOT has
an error.
Check the cable.
0264
Send error
Data cannot be transmitted to the
GOT.
Check the cable.
With the communication dialog for
the GOT-A900 Series,
communication with
non-GOT-A900 Series is
performed.
Connect the GOT-A900 Series.
0289
GOT type error
With the communication dialog for
the GOT-F900 Series,
communication with
non-GOT-F900 Series is
performed.
Connect the GOT-F900 Series.
PC card ( Section 5.3.2 Write method to PC card)
Error No. Error message Error definition and cause Corrective action
The drive where the PC card is set
is not specified.
Select the drive where the PC card
is set in "PC card".
0288
Create Directory Error
The PC card is write protected.
Disable the write protect of the PC
card.
OS is not selected for Installing.
The item to be installed is not
selected.
Select the item to be installed in
the "project configuration tree".
7 or more memories cannot be
selected from the extended function
OS.
Please reduce to a maximum of 6
memoies.
The extended function OS to be
installed exceeds the number of
required memories (6) that can be
installed on the GOT.
Select the extended function OS to
be installed so that the number of
the required memories may be
within 6.
(
Section 5.1.1,
Extended function OS)
CNC monitor and KANA
KANJI(JPN) extended OS are
compatible with ROM_BIOS Ver
9.2.2[W] or later.
When installing to the GOT, please
check that the ROM_BIOS is Ver
9.2.2[W] or later
Continue writing.
OK?
The left message is always
displayed when [CNC monitor] or
[KANA KANJI (JPN)] is selected in
the [Project configuration tree].
Check the ROM_BIOS version
installed within the GOT.
(
Section 5.1.1
ROM_BIOS)