FX
3G
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
5 Operation Test
5.1 Test Procedure
B - 83
A
Common Items
B
Built-in
Positioning
Functions
Apx.
Example
Connection
8 Check the operation in the forward rotation direction.
Check the output indicator lamp (LED lamp) and the current value register to monitor the operation.
The status of the LED indicator lamp and the value indicated in the current value register depend
on the pulse output destination or rotation direction set by the positioning instruction. However, if
the pulse output destination or the rotation direction is changed for the test program, carefully read
the status of the output indicator lamp (LED lamp) and the value indicated in the current value
register to monitor the change.
1. Operation in forward rotation direction
Turn on the forward rotation (JOG+) switch (X012), and verify that the operation is performed in the
forward rotation direction. For this check, set the other inputs as follows:
1) LED indicator lamp check
Check the LED indicator lamps of the PLC or the display module to see whether or not the outputs are
turned on. The status of each output should be as shown in the following table:
2) Current value register (D8341, D8340) check
Monitor the current value register (D8341, D8340) of the FX
3U/FX3UC/FX3G PLC using the programming
tool, and confirm that the value is being increased.
→ For details on the current value register, refer to Subsection 4.4.1.
2. Stop of operation
Turn off the forward rotation (JOG+) switch (X012) to stop the operation in the forward rotation direction.
1) LED indicator lamp check
Check the LED indicator lamps of the PLC or the display module to check whether the outputs are turned
on. The status of each output should be as shown in the following table:
2) Current value register (D8341, D8340) check
Monitor the current value register (D8341, D8340) of the FX
3U/FX3UC/FX3G PLC using the programming
tool, and confirm that the value is not being increased.
→ For details on the current value register, refer to Subsection 4.4.1.
Input signal Status
X010 ON
X011 ON
X013 OFF
Pulse output
method
LED lamp of
output
Status of LED lamp (output)
If transistor outputs of the
main unit are used
"Pulse train + direc-
tion" method
Y000 Turned on and off at high speed.
Y004 Kept ON.
If a high-speed output
special adapter is used
"Pulse train + direc-
tion" method
Y0/2 Turned on and off at high speed.
Y4/6 Kept ON.
Forward rotation
pulse train (FP)
Reverse rotation
pulse train (RP)
Y0/2 Turned on and off at high speed.
Y4/6 Kept OFF.
Pulse output
method
LED lamp
of output
Status of LED lamp (output)
If transistor outputs of the
main unit are used
"Pulse train + direc-
tion" method
Y000
The LED indicator lamp (turned on and
off at high speed) will be turned off.
Y004 Kept ON.
If the high-speed output
special adapter is used
"Pulse train + direc-
tion" method
Y0/2
The LED indicator lamp (turned on and
off at high speed) will be turned off.
Y4/6 Kept ON.
Forward rotation
pulse train (FP)
Reverse rotation
pulse train (RP)
Y0/2
The LED indicator lamp (turned on and
off at high speed) will be turned off.
Y4/6 Kept OFF.