PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
11 Batch Data Positioning Mode (TBL Instruction)
11.4 Positioning Parameter Setting
B - 149
A
Common Items
B
Built-in
Positioning
Functions
Apx.
Example
Connection
*1. Y002 is not available in 14-point and 24-point type FX3G PLC.
*2. Note that this item can only be set if two FX
3U-2HSY-ADP adapters are connected to the FX3U PLC.
*3. To use an FX
3U-2HSY-ADP, set the rotation direction signal depending on the pulse output destination
device as shown in the following table.
*4. 1200 in the FX
3G series PLC.
*5. Only available for FX
3U and FX3UC PLCs.
*6. Up to Y000 to Y177 in the FX
3G series PLC.
*7. Up to D0 to D6800, R0 to R22800 in the FX
3G series PLC.
*8. Refer to the description of the selected instruction (positioning type).
"Insert" button Click this button to insert a line at the specified position. -
"Delete" button Click this button to delete the selected line. -
"Delete All" button
Click this button to delete all the data from the positioning table of the selected
pulse output destination device.
-
Positioning table
setting will not be
initialized when the
PLC is powered on
If this check box is checked, the positioning data will not be initialized when the
PLC power is turned ON. Enter a check in this check box to retain the
changed data ("pulses" and "frequency" changed by the program, display
module, or HMI) even after power-off and to use the changed data after turning
on the power again. To use this function, set an uninterruptible power supply
type device as the first device.
-
"Write" button
Click this button to write 1600 points
*4
of data ("pulses" and "frequency" set on
the positioning table using GX Developer) starting from the first device of the
PLC.
-
"Read" button
Click this button to read out 1600 points
*4
of data ("pulses" and "frequency" set
on the positioning table currently used) from the PLC starting from the first
device. At the completion of data reading, the data numbers will appear only if
"Positioning Instruction" is set for the data.
-
Pulse output destination device Rotation direction signal
Y000 Y004
Y001 Y005
Y002 Y006
Y003 Y007
Positioning type Refer to
DDVIT (Interrupt positioning) Chapter 9
DPLSV (Variable Speed Pulse Output) Chapter 10
DDRVI (Drive to Increment) Section 8.2
DDRVA (Drive to Absolute) Section 8.3
Setting item Description of setting Setting range