4.3.7 Designation of Interrupt Input Signal for DVIT Instruction
The interrupt input signal of the interrupt positioning (DVIT) instruction depends on the pulse output
destination device as shown in the following table.
Use an FX
3UC PLC Ver. 1.30 or later to use the interrupt input specification function.
Use an FX
3U/FX3UC PLC Ver. 2.20 or later to set the user interrupt input command.
For operation of DVIT instruction, refer to Chapter 9.
*1. Devices related to Y003 (pulse output destination) are only valid if two FX
3U-2HSY-ADP adapters are
connected to the FX
3U PLC.
Designation of interrupt input using M8336 interrupt input
specification function:
1) Turn on M8336.
2) Set the interrupt input number (X000 to X007) in D8336, or
specify the user interrupt input command
*1
.
For specifying the settings, refer to the following description.
Pulse output
destination
device
Interrupt input signal
If it is not necessary to use the
interrupt input specification function
(M8336 = OFF), or if an FX
3UC PLC
below Ver. 1.30 is used
If it is necessary to use the interrupt input specification
function (M8336 = ON)
Y000 X000
Y001 X001
Y002 X002
Y003
*1
X003
Setting value Description of setting
0 Specifies X000 for the interrupt input signal.
1 Specifies X001 for the interrupt input signal.
~
~
7 Specifies X007 for the interrupt input signal.
8
*1
Specifies the user interrupt input command
*1
for the interrupt input signal.
9 to E
*3
Do not specify these values.
F
Set "F" for a pulse output destination device if the device is not used for the interrupt
positioning (DVIT) instruction.
D8336=H
{
{
{
{
Interrupt input for Y000
(pulse output destination device)
Interrupt input for Y001
(pulse output destination device)
Interrupt input for Y002
(pulse output destination device)
Interrupt input for Y003
(pulse output destination device)
D8336=H
{
{
{
{
Interrupt input for Y000
(pulse output destination device)
Interrupt input for Y001
(pulse output destination device)
Interrupt input for Y002
(pulse output destination device)
Interrupt input for Y003
(pulse output destination device)
Pulse output destination device User interrupt input command
Y000 M8460
Y001 M8461
Y002 M8462
Y003
*2
M8463