FX
3G
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Example Connection
Appendix 2. MELSERVO-J2 (-Super) Series
Appendix 2-3 Absolute Position Detection (Transistor Output)
Apx. - 14
2. FX
3UC PLC
*1. Be sure to use the class-D grounding method (grounding resistance: 100
Ω
or less).
FX
3UC
-32MT/D
SD
Plate
COM1
FX
2NC
-16EYT
Y020
Y027
COM1
Y021
Y022
Y023
COM
X000
COM
X020
FX
2NC
-16EX
X031
X032
X033
X037
SON
ABSR
ABSM
CN1B
SG
COM
10
13
5
9
8
DO1
TLC
ZSP
4
6
19
Photo-
coupler
Photo-
coupler
24V DC
Class-D
grounding
*1
ABS(bit0)
ABS(bit1)
Servo-ON
ABS transfer mode
ABS request
Send data ready
MR-J2(S)
A
Series servo
amplifier