Mitsubishi Electronics FX3U Coffeemaker User Manual


 
3 Comparison of Specifications
3.2 Comparison of Operation Modes
A - 18
FX
3G
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Common Items
*7. Variable speed pulse output instruction is used to perform this operation.
Operations with acceleration/deceleration are supported in the FX
3U/FX3UC PLC Ver. 2.20 or later and FX3G
PLC.
*8. Operates with acceleration/deceleration.
*9. When interpolation instructions are consecutively set in the program, it will immediately shift to the
next operation. (continuous pass operation).
*10. When the interpolation operation is continuously set in the table operation, it will immediately shift to
the next operation. (Continuation pass function)
Variable-speed operation
The operation will be per-
formed at the operation
speed specified by the PLC.
3
*7
3
3
*8
−−
3
*8
Linear interpolation
The workpiece will travel to
the target position at the
specified vector speed (inter-
polation operation).
−−−
3
*9
3
*10
Circular interpolation
The workpiece will travel to
the specified target position
(x, y) along an arc at the
specified circumferential
speed.
The center coordinate or
radius can be specified.
−−−
Table operation
A positioning control program
can be set with the table.
−−
3
200
points,
maxi-
mum
3
100
points,
maxi-
mum
3
X-/Y-/XY-
axis:
300
points,
maxi-
mum
Manual pulse generator
operation
Manual operation can be per-
formed with the manual pulse
generator.
−−
3
30 kHz,
maxi-
mum
3
2 kHz,
maxi-
mum
3
2 kHz,
maxi-
mum
3
100 kHz,
maxi-
mum
Positioning operation
pattern
Description
Built-in positioning function
FX
3G
/FX
3U
/FX
3UC
PLC
(main unit)
(Transistor output)
FX3U-2HSY-ADP(FX3U)
FX2N-1PG(-E)
FX2N-10PG
FX2N-10GM
FX2N-20GM
FX3U-20SSC-H
Speed
Start Speed
change
Speed
change
Stop
X-axis
Y-axis
Start point
Target
position (x, y)
x
y
CW
Start
point
Target position (x, y)
:cw Dotted line
Solid line
:ccw
Radius: r
Start point
CCW
Target
position
(x, y)
Radius: -r
No. Position Speed
•••
0 200 500
1 500 1000
2 1000 2000
Magnification
Dividing ratio
Input pulse:
30 kHz or less
Phase
A
Phase
B
Servo amplifier
drive unit
Manual pulse
generator