PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
11 Batch Data Positioning Mode (TBL Instruction)
11.4 Positioning Parameter Setting
B - 146
2 Set the memory capacity.
Click on the "Memory capacity" tab, and then click on the "Positioning Instruction Setting" check
box to enter a check in the box.
*1. The initial value is 8000 steps for GX Developer below Ver.8.22Y.
The initial value is "8000 steps" in the FX3G PLC.
*2. Only available for
FX3U and FX3UC PLCs.
Setting item Description of setting Setting range
Memory capacity
Set the capacity of the program memory. Initial value: 16000
*1
Refer to the
programming
manual.
Comment capacity
Set the capacity for the comments to be stored in the PLC. Initial
value: 0
Device comment: 50 points/block (500 steps)
File register capacity
Set the capacity for the file registers. Initial value: 0
File registers: 500 points/block (500 steps)
Program capacity
Displays the number of steps that can be used for the sequence
program.
Special Function Memory
capacity
Set whether the special unit initial data setting function and the
positioning data setting function should be enabled.
-
Special Function Block
Settings
*2
Enter a check in the check box to enable the special function unit/
block initial data setting function. Use the "I/O Assignment Setting"
tab to set the initial value of a special unit.
-
Positioning Instruction
settings
Enter a check in the check box to enable the TBL (FNC152)
instruction setting function. Use the "Positioning Data Setting" tab to
set the positioning data.
-
Enter a check.
*1