A SERVICE OF

logo

SIS
Programming and Control, cont’d
ISS 506 Integration Seamless Switcher • SIS
Programming and Control
4-30
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
PIP window configuration
N
The variables must be entered, and are returned, in the following order: horizontal position*vertical position*horizontal size*vertical size.
Set PIP window’s size and
position
E
3,
X1&
*
X1&
*
X1^
*
X1^
XY
}
Set the size and position of the PIP window
output with a single command.
W3,
X1&
*
X1&
*
X1^
*
X1^
XY
|
3Win
X1&
*
X1&
*
X1^
*
X1^]
View PIP window’s size and
position
E
3XY
}
W3XY
| X1&
*
X1&
*
X1^
*
X1^]
Show the PIP window’s size and position.
PIP image configuration
N
The variables must be entered, and are returned, in the following order: horizontal position*vertical position*horizontal size*vertical size.
Set PIP image’s size and position
E
4,
X1&
*
X1&
*
X1^
*
X1^
XY
}
Set the size and position of the PIP image
output with a single command.
W4,
X1&
*
X1&
*
X1^
*
X1^
XY
|
4Win
X1&
*
X1&
*
X1^
*
X1^]
View PIP image’s size and position
E
4XY
}
W4XY
| X1&
*
X1&
*
X1^
*
X1^]
Show the PIP image’s size and position.
Optional Scan converter board
Output format
Set scan converter output format
36*
X3(
# Tpo
X3(]
Set the output format for the optional scan
converter.
View scan converter output format 36#
X3(]
View the scan converter output format.
Output standard
Set scan converter output standard
37*
X4)
# Std
X4)]
Set the output standard for the optional scan
converter.
View scan converter output
standard
37#
X4)]
View the scan converter output standard.
Horizontal position
Specify horizontal position
7*
X1&
H 7*
X1&
H 7Hph
X1&]
Specify the horizontal position of the scan
converted output.
Increment right 7+H 7+H
7Hph
X1&]
Move the scan converted output one pixel right.
Increment left 7-H 7-H
7Hph
X1&]
Move the scan converted output one pixel left.
View the horizontal position 7H 7H
X1&]
Show the horizontal position of the first pixel.
Command/response table for SIS commands (continued)
N
X1^
= Size Up to 4095
X1&
= Position value Up to 4095
X3(
= Scan converter board type 0 = composite/S-video 1 = YUV 2 = RGsB
X4)
= Scan converted output type 0 = NTSC 1 = PAL