ISS 506 Integration Seamless Switcher • HTML Operation
7. The switcher checks several possibilities, in the following order, and then
responds accordingly:
•
Does the address include a specific file name, such as 10.13.156.10/
file_name.html? If so, the switcher downloads that HTML page.
•
If not, is there a file in the switcher’s memory that is named “index.html”?
If so, the switcher downloads “index.html” as the default startup page.
•
If neither of the above conditions is true, the switcher downloads the
factory-installed default startup page, “nortxe_index.html” (figure 6-2),
also known as the System Status page.
N
On password-protected connections, there are two levels of protection:
administrator and user.
Administrators have full access to all pages described in this chapter and all
switching capabilities and editing functions.
When you are logged on as a user, only the Status and Control tabs are shown on
the Web pages. Users have access only to the User Control, Presets, PIP Setup,
and Logos pages.
System Status Tab
The System Status page (figure 6-2) provides an overall, read-only view of the
status of the seamless switcher, including individual voltages, and serial port
status (if applicable). The System Status page is the default page that the switcher
downloads when you connect to the switcher. Access the System Status page from
other pages by clicking the Status tab.
Figure 6-2 — System Status page
The status web page does not automatically update. If you want to see an update,
click the Refresh button on your Web browser.