Emerson 300510EN Yogurt Maker User Manual


 
System Configuration Manual
300510EN, Rev AA
December 2010
5-67
Rosemount Raptor
Section 5. Installing a Raptor Level Gauging System
5.8.2 Communication Parameter Setup
The Communication tab lets you verify the ATD communication settings.
1. In the 22xx ATD window select the Communication tab:
2. In the Connected to HUB field verify that the ATD device is connected to
the correct 2410 Tank Hub and mapped to the correct tank position in the
2410 tank database.
For example, “position 1” means that the ATD device is mapped to tank
database position 1, “position 2” to tank database position 2 etc.
You can check the tank database of the current 2410 Tank Hub by
opening the 2410 HUB Properties/Tank Database window. See
“Installing a Rosemount 2410 Tank Hub” on page 5-38 for more
information on the 2410 Tank Database.
3. The Change button lets you change the Modbus address of the current
ATD device in case the ATD device is connected to a multiple tank
version of the 2410 Tank Hub.
Note that the Modbus address can only be changed for ATD devices in
tank database position 2 and higher. An ATD device mapped to
position 1 in the 2410 tank database uses the same Modbus address as
the 2410 Tank Hub itself. See “Installing a Rosemount 2410 Tank Hub”
on page 5-38 for more information.
4. Click the Apply button to store the configuration, or click the OK button