System Configuration Manual
300510EN, Rev AA
December 2010
5-25
Rosemount Raptor
Section 5. Installing a Raptor Level Gauging System
5.5 INSTALLING A ROSEMOUNT 2160 FCU
5.5.1 Introduction Installing a Rosemount 2160 Field Communication Unit (FCU) in a
Rosemount Raptor system includes the following basic steps:
1. Specify device type and name tag.
2. Enable communication with the TankMaster PC.
3. Configure the Group bus and Field bus ports for communication with
Rosemount 2410 Tank Hubs and TankMaster work stations.
4. Configure the Slave Database.
Configuration examples that illustrate how the 2160 Slave Database is related
to the Tank Database of a 2410 Tank Hub is shown in “Examples of 2160 FCU
Slave Database Configuration” on page 5-32.
5.5.2 Installation
Procedure
To install and configure a 2160 FCU do the following:
1. Start the device installation wizard. See “Using the Device Installation
Wizard” on page 5-5 for more information.
2. Select device type:
a. Choose device type FCU 2160.
b. Specify a name of the Field Communication Unit in the FCU Tag
input field. This tag will be used as an identifier when the Rosemount
2160 is shown in various windows and dialogs. The TankMaster
program automatically suggests the first part of the name as
specified in the Tag Prefixes window, see “Setting the Name Tag
Prefixes” on page 5-20.
c. Click the Next button to continue the installation procedure.