System Configuration Manual
300510EN, Rev AA
December 2010
Rosemount Raptor
5-40
Section 5. Installing a Raptor Level Gauging System
Communication Setup
6. Specify whether TankMaster communicates directly with the 2410 Tank
Hub, or via a 2160 Field Communication Unit.
7. If the 2410 Tank Hub is connected to a 2160 FCU, select the appropriate
2160 from the FCU Tag drop-down list.
8. If the 2410 is connected directly to a TankMaster PC and not via a 2160
FCU, specify the communication protocol channel which is associated
with the communication port on the TankMaster workstation. To check
which channels are enabled:
a. in the WinSetup workspace open the Protocols folder
b. click the right mouse button on the ModbusMaster protocol icon
c. choose the Properties option
To check which communication port that is associated with a certain
channel:
a. right-click the protocol channel icon
b. open the Communication tab and check which communication port
that is selected.
See chapter “Master Protocol Channel Configuration” on page 5-7 for
more information on how to configure communication protocols.