Emerson 300510EN Yogurt Maker User Manual


 
System Configuration Manual
300510EN, Rev AA
December 2010
Rosemount Raptor
5-72
Section 5. Installing a Raptor Level Gauging System
5.8.5 Auxiliary Sensor Configuration
The 2240S MTT Auxiliary Sensor tab lets you configure a water level sensor
connected to a Rosemount 2240S Multi-input Temperature Transmitter.
All input fields in the 2240S MTT Auxiliary Sensor tab will be disabled if no
2240S Multi-input Temperature Transmitter is associated with the current tank
position in the tank database of the 2410 Tank Hub.
Water Level Sensor
This section gives a brief description of how to configure a water level sensor
connected to the Rosemount 2240S Multi-input Temperature Transmitter. See
the Rosemount 2240S Multi-Input Temperature Transmitter Reference
Manual (Document No. 300550EN) for further information.
To configure the water level sensor do the following:
1. In the 22xx ATD window, select the 2240S MTT Auxiliary Sensor tab:
2. Calculate the Level Offset (X) according to the formula X=(R-L1)-(L-L2).