Sony CCp-8000 Water Dispenser User Manual


 
Chapter 14 Snapshots
162
Snapshot Operations From the Numeric Keypad Control Block
The display shows the name of the reference region and the number of the
register previously recalled for that region.
3
Enter the desired register number from the numeric keypad.
See step 5 (page 160) in “Saving a snapshot from the numeric keypad
control block.”
The entered register number appears in the display.
4
To apply temporary attributes, press the following buttons, turning them
on.
a) When Xpt Hold mode is selected in setup.
b) When Key Disable mode is selected in setup.
For details of temporary attributes and available attributes, see “Snapshot
Attributes” in Chapter 1 (Volume 1).
Notes
The cross-point hold and key disable settings are maintained until you
next press the [XPT HOLD] button.
Applying temporary attributes does not affect the contents of the
register.
It is not possible to apply temporary attributes to a master snapshot.
5
Press the [ENTER] button.
This recalls the specified snapshot, and the reference region name and
recalled register number appear in the display.
If you applied the effect dissolve or auto transition temporary attributes in
step 4, the corresponding buttons go off.
When a master snapshot is recalled, the region selection buttons light
according to the saved region information.
To cancel a snapshot recall operation
After saving a snapshot, to cancel the recall, press the [UNDO] button.
Control block Temporary
attribute to apply
Button
Cross-point control
block
A/B bus cross-point
hold
[XPT HOLD] button in the
background A/B bus
Key cross-point hold
[XPT HOLD] button in the key bus
a)
Key disable
[XPT HOLD] button in the key bus
b)
Numeric keypad
control block
Effect dissolve [+//EFF DISS] button
Auto transition [CLR/AUTO TRANS] button