Chapter 16 Engineering Setup
286
Setup Relating to Router Interface and Tally
2
Use the knobs to select the copy source and copy destination.
3
Press [Execute].
This updates the tally copy settings.
Deleting tally copy settings
Use the following procedure.
1
In the Router/Tally>Tally Copy menu, using either of the following
methods, select the tally copy whose settings you want to delete.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob to make the setting.
2
Press [Delete].
This deletes the selected tally copy entry.
Parallel Tally Settings (Parallel Tally Menu)
For settings relating to parallel tally, use the Router/Tally>Parallel Tally menu.
To display the Parallel Tally menu
In the Engineering Setup menu, select VF6 ‘Router/Tally’ and HF6 ‘Parallel
Tally.’
The status area shows the parallel tally settings.
Making or modifying parallel tally settings
Use the following procedure.
Knob Parameter Adjustment Setting values
1 Copy From Copy-from source 1 to 1024
2 Copy To Copy-to source 1 to 1024
Knob Parameter Adjustment Setting values
1 Copy No Tally copy setting selection for deletion 1 to ...