Sony CCp-8000 Water Dispenser User Manual


 
Chapter 16 Engineering Setup
212
Setup Relating to Operations From the Control Panel
Turn the knob to make the setting.
4
Select the assignment for the [PTN LIMIT], [LIMIT SET], and [KF]
buttons in the standard type transition control block from the <PTN
LIMIT/LIMIT SET/KF Button Assign> group.
Ptn Limit /KF: These are used as the [PTN LIMIT] button, [LIMIT SET]
button, and [KF] button.
Play/Stop/Cue: These are used as the [PLAY] button, [STOP] button, and
[CUE] button for VTR operation.
Inhibit: Inhibit operations with these buttons.
5
Select the assignment for the [NORM], [NORM/REV], and [REV] buttons
in the standard type transition control block from the <NORM/NORM
REV/REV Button Assign> group.
Normal/Reverse: These are used as the [NORM] button, [NORM/REV]
button and [REV] button.
Play/Stop/Cue: These are used as the [PLAY] button, [STOP] button, and
[CUE] button for VTR operation.
Inhibit: Inhibit operations with these buttons.
Cross-Point Settings (Xpt Assign Menu)
To carry out the cross-point settings, use the Panel>Xpt Assign menu.
To display the Xpt Assign menu
In the Engineering Setup menu, select VF2 ‘Panel’ and HF2 ‘Xpt Assign.’
The status area shows button numbers of the cross-point buttons, and the
assigned video/key source names, and source name display color.
Assigning signals to cross-point buttons
For each button number, a pair consisting of a video signal and a key signal is
assigned. You can also assign the same signal to another button number at the
same time.
When carrying out key operations on a bank, if the key fill and key source
selection mode is set to [Auto Select], the signals are selected according to this
pair setting. (See “Selecting Key Fill and Key Source” in Chapter 4 (Volume
1).)
To assign a video signal or key signal to cross-point buttons, proceed as
follows.
Knob Parameter Adjustment Setting values
1 Bank Bank selection 1 to 4