Cisco Systems DOC-7812945= Blender User Manual


 
11-12
Cisco WAN Manager Users Guide
Version 10.5, Part Number 78-12945-01 Rev. D0, August 2003
Chapter11 CWM to CWM Communications
Recovering From Degrade Mode
The following is an example of the downed Primarys DomainGatewayList. Remove all Secondary
CWMs from the downed Primarys DomainGatewayList leaving the Primary cwmws1 in its own
domain:
Debug level 2
DomainGatewayList cwmws1
ForcedSwitchOver
HeartBeatInterval 20
Step 3 Stop the core on the downed Primary CWM (to prevent communication with the Secondary CWMs while
the Primary is down and isolated).
Step 4 Stop the core on the Secondary CWM that has been selected as the new Primary. In this case, for
example, lets say that cwmws2 has been selected as the new Primary.
Step 5 Edit the new Primarys DomainGatewayList so that it only has itself listed. For example:
Debug level 2
DomainGatewayList cwmws2
ForcedSwitchOver
HeartBeatInterval 20
Step 6 Start the core on the new Primary CWM (in this example it would be cwmws2). A message will appear
on the CWM console announcing it as the new Primary.
Step 7 Stop the core on the Secondary CWM (in this example it would be cwmws3).
Step 8 Edit the Secondarys DomainGatewayList so that it includes itself and the new Primary. For
example:
Debug level 2
DomainGatewayList cwmws2 cwmws3
ForcedSwitchOver
HeartBeatInterval 20
Step 9 Edit the new Primarys DomainGatewayList so that it now includes itself and the secondary CWM.
For example:
Debug level 2
DomainGatewayList cwmws2 cwmws3
ForcedSwitchOver
HeartBeatInterval 20
Step 10 Start the core on the Secondary CWM (in this example it would be cwmws3).
Step 11 Repeat steps 7-10 above to include any additional Secondary CWMs in the new domain. The
DomainGatewayList on all of the Secondary CWMs must match the final DomainGatewayList on
the Primary CWM. This list will include the new Primary and all new Secondaries in the new
domain.
The Primary CWM has lost IP or physical connectivity with the only Secondary
CWM in a domain
Note In a situation where there is a Primary CWM and only one Secondary CWM in a given domain,
and connectivity between the two CWMs is lost, another Secondary CWM will need to be added
to the domain before stopping the core on the original Secondary CWM.