Install and configure ITG ISL Trunk node
553-3001-202 Standard 1.00 April 2000
d IP addresses
Note:
If you are installing ITG ISL Trunk Node from a MAT PC on a
remote subnet, and you cannot communicate with the Leader 1 and
the follower cards after transmitting the node properties, card
properties and dialing plan to Leader 0 and rebooting the Leader 0
card, this means that the Leader 1 and the follower cards are unable to
communicate back to the remote MAT PC through the default IP route
that points to the voice gateway (router) on the T-LAN.
To establish communication with Leader 1 and the Follower cards from
a MAT PC on a remote subnet, you must connect a local terminal to the
maintenance port on the faceplate of the Leader 1 and Follower cards
and use the ITG shell command ’routeAdd’ on Leader 1 and each
Follower card to add a new IP route for the remote MAT PC subnet that
points to the Management Gateway (router) IP address. Repeat this
step every time a card is reset until the card properties (containing the
card routing table entry IP addresses) have been successfully
transmitted to each card.
ITG> routeAdd “xxx.xxx.xxx.xxx”, “yyy.yyy.yyy.yyy”,
where:
xxx.xxx.xxx.xxx is the IP address of the remote MAT PC, and
yyy.yyy.yyy.yyy is the IP address of the management gateway on the
E-LAN.
Press
Enter
.
2
Verify that the TN, management interface MAC addresses, and IP
addresses are configured correctly for each ITG card. Select any card
in the ITG node in the MAT ITG ISDN IP Trunk main window, and select
menu Configuration | Node | Properties from the drop-down menus.
Compare the values displayed on the “General” tab and the “Card
Configuration” tab with those on the ITG Trunk Installation Summary
Sheet. The ITG - Transmit Options dialog box appears.
3
Correct errors and retransmit Node Properties
4
Reboot all cards for which Node Properties have changed.
Transmit Card Properties and Dialing Plan to Leader 1
and Follower cards
Verify that the ITG Trunk cards are disabled in the Meridian 1 before
transmitting card properties.