321 Studios (ITG) Trunk 2.0 Coffeemaker User Manual


 
Page 228 of
378
Install and configure ITG ISL Trunk node
553-3001-202 Standard 1.00 April 2000
5 a. If you are transmitting new software to a node containing cards of
the same density:
Make sure
Transmit to selected nodes
is selected.
Check
Card software
checkbox.
Click
Browse
and locate the software file for the card density of
the selected node.
Click
Start Transmit
. The software is transmitted to each card in
turn and burned into the flash ROM on the ITG card. Monitor the
progress of the card software transmission in the Transmit Control
window. ITG indicates success or failure of card software
transmission by card TN. Scroll to verify that transmission was
successful for all card TNs. The cards continue to run the old
software until rebooted.
Click the
Close
button and go to step 6.
b.
If you are transmitting new software to a node containing a mix of
card densities:
Make sure
Transmit to selected cards
is selected.
Check
Card software
checkbox.
Click
Browse
and locate the software file for the card density of
the selected cards (24-port or 8-port).
Click
Start Transmit
. The software is transmitted to each card in
turn and burned into the flash ROM on the ITG card. Monitor the
progress of the card software transmission in the Transmit Control
window. ITG indicates success or failure of card software
transmission by card TN. Scroll to verify that transmission was
successful for all card TNs. The cards continue to run the old
software until rebooted.
Click
Close
button.
Repeat steps 3b, 4 and 5b for the other card density.