The Graphical Waveform Editor
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-71
5. Push the Cancel side button.
This cancels the Set Pattern dialog box but retains the pattern data in the pattern
buffer.
6. Open or make active the other editor window.
7. Move the cursors to specify the edit area in which to replace the existing data
with the pattern data.
8. Push Operation (bottom)!Set Pattern... .
The Set Pattern dialog box appears, with the pattern field displaying the pattern
data from the other editor window.
9. Select Data, Marker1, or Marker2 to specify the target data type to replace
with the pattern data.
10. Push the OK side button to replace the waveform or marker data with the
specified pattern data.
Numeric Input...
The Numeric Input... command lets you change the waveform or marker data value
at the active cursor location. You can use the numeric buttons or the general
purpose knob to change the waveform data value.
Do the following steps to change the numeric value of the data at the active cursor
position:
1. Move a cursor to the data point that you want to change.
2. Push Operation (bottom)!Numeric Input... (pop–up)!OK (side).
3. Push the Data side button and use the general purpose knob or numeric keys
to set the waveform data value.
4. Push the Marker1 or Marker2 button to toggle between the marker values.
NOTE. The values modified through the side menu are immediately shown in the
data. Use the general purpose knob after the value has been modified. Push Undo!
to return to the previous value prior to modification.