Appendix B: Performance Verification (AWG710)
AWG710&AWG710B Arbitrary Waveform Generator User Manual B-95
Figure B-58: Waveform output when the SW3 is closed
c. Open SW3 of the ground closure to degenerate the event signal.
d. Verify that the oscilloscope displays the waveform in Figure B-55.
10. Check the EVENT IN connector pin 3 input:
a. Close the SW4 of the ground closure to generate an event signal on the
EVENT IN connector pin 3.
b. Verify that the oscilloscope displays the waveform shown in Figure B-59.
Figure B-59: Waveform output when SW4 is closed
c. Open SW4 of the ground closure to degenerate the event signal.