Synchronous Operation Mode (AWG710B only)
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-255
Connection with Slave
Connection and disconnection with Slave are performed by Master using the
Connect to Slave and Disconnect menu.
1. Push SETUP (front-panel)!Connect(bottom) !Connect to Slave (side)
button to connect to the slave AWG710B.
2. Push SETUP (front-panel)!Connect(bottom) !Disconnect (side) button to
disconnect to the slave AWG710B.
In the following cases, the connection between Master and Slave is canceled
automatically.
The LAN cable is unplugged from the connector.
The power of Slave was turned off.
Master or Slave was changed from Synchronous Operation mode.
When executing Diagnostic or Calibration of the UTILITY menu.
Error messages on connection
When making connection with Slave in Synchronous Operation mode, the
AWG710B is also performing Trigger Timing CAL automatically.
The following error/warning messages may be displayed during operation in
Synchronous Operation mode.
Table 3-59: Error/Warning messages
Message Description
Gated is not available in Synchronous Operation.Run
Mode will be changed to Continuous.
It is the warning message which comes out when it is going to go into
Sync-Master, where Gated is specified by Run Mode. Ruined switches to
Continuous.
External Clock Source or External Clock Reference is not
available in Synchronous Operation - Slave. Clock Source
and Clock Reference will be changed to Internal
It is the warning message which comes out when it is going to go into
Sync-Slave, where External is specified by ClockSource or by
ClockReference. As for the Slave itself, Clock and Reference Clock operate in
the state of Internal.
Connection will be lost. It is displayed, when connection between Master and Slave is established and
it is going to perform Calibration/Diagnostics of the UTILITY menu.