Tektronix AWG710B Ventilation Hood User Manual


 
The UTILITY Window
3-178 AWG710&AWG710B Arbitrary Waveform Generator User Manual
7511 to 7514 5dB attenuator 1 test error (CH1 to CH1)
7520 5dB attenuator 2 test error
7521 to 7524 5dB attenuator 2 test error (CH1 to CH1
)
7530 10dB attenuator test error
7531 to 7534 10dB attenuator test error (CH1 to CH1
)
7540 20dB attenuator test error
7541 to 7544 20dB attenuator test error (CH1 to CH1
)
7610 20 MHz filter test error
7611 to 7614 20 MHz filter test error (CH1 to CH1)
7620 50 MHz filter test error
7621 to 7624 50 MHz filter test error (CH1 to CH1
)
7630 100 MHz filter test error
7631 to 7634 100 MHz filter test error (CH1 to CH1
)
7640 200 MHz filter test error
7641 to 7644 200 MHz filter test error (CH1 to CH1
)
7700 to 7704 Reference level test error
Waveform/Sequence 9111 Load error, memory full
9112 Load error, invalid waveform length
9113 Load error, waveform length too short
9114 Load error, waveform length changed
7700 to 7704 Reference level test error
Sequence 9121 Load error, missing file name in sequence
9122 Load error, too many nesting levels
9123 Load error, infinite loop in sub–sequence
9124 Load error, infinite sub–sequence level
9125 Load error, max sequence elements
exceeded
9126 Load error, invalid jump address
9127 Load error, sequence memory full
9128 Load error, infinite loop and Goto One not
allowed
9129 Load error, infinite loop and Goto <N> not
allowed
Waveform 9151 Load warning, output disabled in some
channels
Waveform/Sequence 9152 Output warning, output disabled
Table 3-45: Diagnostic categories and error codes (cont.)
Categories Error codes Descriptions