Tektronix AWG710B Ventilation Hood User Manual


 
FG Mode
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-237
Amplitude
The amplitude output voltage range is from 0.020 V
p–p
to 2.000 V
p–p
(Option 02:
0.500 V
p–p
to 1.000 V
p–p)
, in 1 mV increments, terminated into a 50 load. Set
the waveform amplitude using the LEVEL / SCALE knob, the numeric buttons or
the general purpose knob.
Offset (except option 02)
The offset range is from -0.500 V to +0.500 V, in 1 mV increments. Use the
VERTICAL OFFSET knob, the numeric buttons or the general purpose knob to set
the waveform offset level.
Offset is also used for setup of DC level.
Polarity
This menu sets the output waveform polarity. Pushing the Polarity menu button
toggles polarity between Normal and Inverted.
Duty
When you select Pulse waveform, Duty... side menu is added. The Duty cycle is
set from 0.1% to 99.9% using the numeric buttons or the general purpose knob.
Increment step size depends on the output frequency. Refer to Table 3-56 on page
3-239.
Table 3-54: Output frequency and filter cut–off frequency (except option02)
Waveform type Output Frequency Filter Cut-off Frequency
Sine 1.000 Hz to 400.0 kHz
400.1 KHz to 4.000 MHz
4.001 MHz to 8.000 MHz
8.001 MHz to 15.00 MHz
20 MHz
50 MHz
100 MHz
200 MHz