Tektronix AWG710B Ventilation Hood User Manual


 
The APPL Menu
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-135
Isolated Pulse
Isolated pulse lets you superpose a pulse onto the converted code. You can select
from the following five pulse types:
Lorentz/Gaussian pulse
Isolated pulse is created by the mixture of two types waveforms; Lorentz and
Gaussian. You can adjust mixture rate through Lorentz/Gaussian: parameters
displayed in the lower part of the screen.
When you adopt complete Lorentz waveform as an isolated pulse, set the
parameter to [100] / [ 0]%. When you adopt Gaussian waveform as an isolated
pulse, set the parameter to [ 0] / [100]%.
Mixed waveform is acquired by adding two formulas which have same PW50
and normalizing the calculated value. Each formula is set to L(x) and G(x), and
the mixture rate is set to a and b respectively.
Isolated pulse: Normalize (a*L(x) + b*G(x))
(a + b = 1.0)
PR4 pulse
EPR4 pulse
E2PR4 pulse
User defined pulse
You can define isolated pulse. Create user-defined waveform on the internal
disk. There are two options for creating user–defined file; using editor or using
signals acquired by oscilloscope. Follow the procedures described below to
create the isolated pulse.