Tektronix AWG710 Ventilation Hood User Manual


 
The Graphical Waveform Editor
3-62 AWG710&AWG710B Arbitrary Waveform Generator User Manual
1. Move an active cursor to the location in the waveform record where you want
to insert the data.
2. Push Operation (bottom)!Multiple Paste (pop–up)!OK (side).
The instrument displays a dialog box in which you can enter the number of
times to insert the paste buffer contents.
3. Set the paste count by using the numeric buttons or the general purpose knob.
4. Push the OK side button.
The contents of the paste buffer are inserted the specified number of times at
the active cursor position.
Set Data High/Low
The Set Date High/Low command sets all Marker 1 or 2 values that are between
the two cursors to High or Low. Do the following steps to set the marker values:
1. Move the cursors to specify the edit area that you want to change.
2. Push Operation (bottom)!Set Data High/Low (pop–up)!OK (side).
3. Push the Marker 1 or Marker 2 side button to select the marker.
4. Push the Set Data side button to toggle between High and Low value.
5. Push the Exec side button to change the marker specified in Step 3 to the value
specified in Step 4 for the entire edit area.
Horizontal Shift...
The Horizontal Shift... command shifts the edit area data to the left or right by the
specified value (points or time), within the cursor area. A positive value shifts data
to the right, and a negative value shifts data to the left. All data that is shifted past
the left or right cursor is truncated. The opposite, blanked field is padded with the
initial cursor point values. This command can only shift one type of data
(waveform, Marker 1 or Marker 2) at a time.
Do the following steps to horizontally shift the waveform or the marker data:
1. Move the cursors to specify the edit area of data to shift.
2. Push Operation (bottom)!Horizontal Shift (pop–up)!OK (side).
3. Push the Data, Marker1, or Marker2 side button to select the data you want
to shift.
4. Push the Point (or Time) side button.