Tektronix AWG710 Ventilation Hood User Manual


 
The Graphical Waveform Editor
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-63
Use the general purpose knob or numeric keys to specify the amount of shift.
A positive value shifts data to the right, and a negative value shifts data to the
left.
5. Push the Exec side button to shift the part specified in step 3 by the amount
specified in step 4.
Horizontal Rotate...
The Horizontal Rotate... command rotates the edit area data to the left or right by
the specified value (points or time), within the cursor area. A positive value shifts
data to the right, and a negative value shifts data to the left. All data that is shifted
past the left or right cursor is rotated to the opposite cursor. This command can only
shift one type of data (waveform, Marker 1 or Marker 2) at a time.
Do the following steps to horizontally rotate waveform or marker data:
1. Move the cursors to specify the edit area to shift.
2. Push Operation (bottom)!Horizontal Rotate (pop–up)!OK (side).
3. Push the Data, Marker1, or Marker2 side button to select the data you want
to shift.
4. Push the Point (or Time) side button. Use the general purpose knob or numeric
keys to specify the amount of shift. A positive value shifts data to the right, and
a negative value shifts data to the left.
5. Push the Exec side button to shift the part specified in step 3 by the amount
specified in step 4.
Vertical Shift...
The Vertical Shift... command shifts the cursor–to–cursor waveform data up or
down the value specified with Value. If Value is positive, the data shifts up; if
Value is negative, the data shifts down. The editor retains values that exceed the
default ±1.0 waveform peak–to–peak range. You can use the Zoom or Pan
commands to view data that is out of the waveform display range. You can only
vertically shift waveform data; you cannot vertically shift marker data.
Do the following steps to vertically shift waveform data:
1. Move the cursors to specify the edit area to shift.
2. Push Operation (bottom)!Vertical Shift (pop–up)!OK (side).
3. Push the Value side button. Specify the amount of shift using the general
purpose knob or numeric buttons. A positive value shifts data up, and a
negative value shifts data down.
4. Push the Exec side button to shift the waveform by the amount you specified
in Step 3.